{"id":14209,"date":"2025-07-08T11:23:19","date_gmt":"2025-07-08T04:23:19","guid":{"rendered":"https:\/\/demo8.alumagubi.com\/alumaid\/?p=14209"},"modified":"2025-07-09T16:29:16","modified_gmt":"2025-07-09T09:29:16","slug":"avc-6-ecs-advancediq-vent-controller","status":"publish","type":"post","link":"https:\/\/demo8.alumagubi.com\/alumaid\/avc-6-ecs-advancediq-vent-controller\/","title":{"rendered":"AVC-6 ECS AdvancedIQ Vent Controller"},"content":{"rendered":"<h2>AVC-6 ECS AdvancedIQ Vent Controller<\/h2>\n<h6>Nitrogen Generator Corrosion Monitoring<\/h6>\n<h2>General Description<\/h2>\n<p>The ECS AdvancedIQ Vent Controller provides automatic oxygen venting and monitoring of nitrogen\/oxygen concentration levels within each dry\/preaction fire sprinkler system. As a fire sprinkler system is filled with a continuous supply of nitrogen gas from the ECS AdvancedIQ Nitrogen Generator System, the ECS Standard Vent, installed on the sprinkler system riser, allows oxygen-rich gas to be vented from the fire sprinkler system. The AVC samples the discharge gas from each ECS Standard Vent connected to the controller. Over a fourteen (14) day period, the ECS Standard Vent will dilute the oxygen concentration in the fire sprinkler system to &lt;2% oxygen. The gas flows out of the restricted orifice on the vent through pressure rated tubing to provide slow controlled flow to the AdvancedIQ Vent Controller. Once the desired system gas composition is reached the controller will automatically close and stop the venting process thereby preventing continuous venting. One AVC is capable of individually controlling and monitoring up to six (6) ECS Standard Vents on six (6) separate fire sprinkler systems. <\/p>\n<p>The AdvancedIQ HMI display screen allows for easy operation and complete control of the AVC as well as the ability to monitor from anywhere in the world via ECS GreenSight. Access to AVC operation, maintenance, diagnostics and stored historical data is easily obtained through the HMI screen on the vent controller or remotely through the internet via ECS GreenSight.<\/p>\n<p>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"257\" height=\"54\" src=\"https:\/\/demo8.alumagubi.com\/alumaid\/wp-content\/uploads\/2025\/05\/image-mep.png\" alt=\"\" sizes=\"100vw\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/p>\n<h2>Features<\/h2>\n<ul>\n<li>\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 136.967-111.033 248-248 248S8 392.967 8 256 119.033 8 256 8s248 111.033 248 248zM227.314 387.314l184-184c6.248-6.248 6.248-16.379 0-22.627l-22.627-22.627c-6.248-6.249-16.379-6.249-22.628 0L216 308.118l-70.059-70.059c-6.248-6.248-16.379-6.248-22.628 0l-22.627 22.627c-6.248 6.248-6.248 16.379 0 22.627l104 104c6.249 6.249 16.379 6.249 22.628.001z\"><\/path><\/svg><br \/>\n\t\t\t\t\t\t\t\t\t\tInteractive LCD touchscreen display\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 136.967-111.033 248-248 248S8 392.967 8 256 119.033 8 256 8s248 111.033 248 248zM227.314 387.314l184-184c6.248-6.248 6.248-16.379 0-22.627l-22.627-22.627c-6.248-6.249-16.379-6.249-22.628 0L216 308.118l-70.059-70.059c-6.248-6.248-16.379-6.248-22.628 0l-22.627 22.627c-6.248 6.248-6.248 16.379 0 22.627l104 104c6.249 6.249 16.379 6.249 22.628.001z\"><\/path><\/svg><br \/>\n\t\t\t\t\t\t\t\t\t\tPressure &#038; purity monitoring for up to 6 zones\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 136.967-111.033 248-248 248S8 392.967 8 256 119.033 8 256 8s248 111.033 248 248zM227.314 387.314l184-184c6.248-6.248 6.248-16.379 0-22.627l-22.627-22.627c-6.248-6.249-16.379-6.249-22.628 0L216 308.118l-70.059-70.059c-6.248-6.248-16.379-6.248-22.628 0l-22.627 22.627c-6.248 6.248-6.248 16.379 0 22.627l104 104c6.249 6.249 16.379 6.249 22.628.001z\"><\/path><\/svg><br \/>\n\t\t\t\t\t\t\t\t\t\tDatalogging &#038; historical trends for each zone\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 136.967-111.033 248-248 248S8 392.967 8 256 119.033 8 256 8s248 111.033 248 248zM227.314 387.314l184-184c6.248-6.248 6.248-16.379 0-22.627l-22.627-22.627c-6.248-6.249-16.379-6.249-22.628 0L216 308.118l-70.059-70.059c-6.248-6.248-16.379-6.248-22.628 0l-22.627 22.627c-6.248 6.248-6.248 16.379 0 22.627l104 104c6.249 6.249 16.379 6.249 22.628.001z\"><\/path><\/svg><br \/>\n\t\t\t\t\t\t\t\t\t\tManual leak rate checks for each zone\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 136.967-111.033 248-248 248S8 392.967 8 256 119.033 8 256 8s248 111.033 248 248zM227.314 387.314l184-184c6.248-6.248 6.248-16.379 0-22.627l-22.627-22.627c-6.248-6.249-16.379-6.249-22.628 0L216 308.118l-70.059-70.059c-6.248-6.248-16.379-6.248-22.628 0l-22.627 22.627c-6.248 6.248-6.248 16.379 0 22.627l104 104c6.249 6.249 16.379 6.249 22.628.001z\"><\/path><\/svg><br \/>\n\t\t\t\t\t\t\t\t\t\tOptional remote monitoring and email alerts\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 136.967-111.033 248-248 248S8 392.967 8 256 119.033 8 256 8s248 111.033 248 248zM227.314 387.314l184-184c6.248-6.248 6.248-16.379 0-22.627l-22.627-22.627c-6.248-6.249-16.379-6.249-22.628 0L216 308.118l-70.059-70.059c-6.248-6.248-16.379-6.248-22.628 0l-22.627 22.627c-6.248 6.248-6.248 16.379 0 22.627l104 104c6.249 6.249 16.379 6.249 22.628.001z\"><\/path><\/svg><br \/>\n\t\t\t\t\t\t\t\t\t\tEasy installation and setup\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 136.967-111.033 248-248 248S8 392.967 8 256 119.033 8 256 8s248 111.033 248 248zM227.314 387.314l184-184c6.248-6.248 6.248-16.379 0-22.627l-22.627-22.627c-6.248-6.249-16.379-6.249-22.628 0L216 308.118l-70.059-70.059c-6.248-6.248-16.379-6.248-22.628 0l-22.627 22.627c-6.248 6.248-6.248 16.379 0 22.627l104 104c6.249 6.249 16.379 6.249 22.628.001z\"><\/path><\/svg><br \/>\n\t\t\t\t\t\t\t\t\t\tRemoveable datalog (flash drive)\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 136.967-111.033 248-248 248S8 392.967 8 256 119.033 8 256 8s248 111.033 248 248zM227.314 387.314l184-184c6.248-6.248 6.248-16.379 0-22.627l-22.627-22.627c-6.248-6.249-16.379-6.249-22.628 0L216 308.118l-70.059-70.059c-6.248-6.248-16.379-6.248-22.628 0l-22.627 22.627c-6.248 6.248-6.248 16.379 0 22.627l104 104c6.249 6.249 16.379 6.249 22.628.001z\"><\/path><\/svg><br \/>\n\t\t\t\t\t\t\t\t\t\tForm C dry contact supervisory signal\n\t\t\t\t\t\t\t\t\t<\/li>\n<\/ul>\n<h2>Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<td style=\"text-align: right; font-weight: bold; width: 50%;\">Cabinet Dimensions<\/td>\n<td>:<\/td>\n<td>12\u201d (W) x 14\u201d (H) x 8\u201d (D)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right; font-weight: bold;\">Weight<\/td>\n<td>:<\/td>\n<td>24 Lbs 1<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right; font-weight: bold;\">Power Supply (dedicated circuit) Sensing<\/td>\n<td>:<\/td>\n<td>20-240VAC, 50-60Hz\/.5A<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right; font-weight: bold;\">Inputs<\/td>\n<td>:<\/td>\n<td>Six (6)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right; font-weight: bold;\">Internet Connection<\/td>\n<td>:<\/td>\n<td>LAN<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right; font-weight: bold;\">Signal Output<\/td>\n<td>:<\/td>\n<td>Common Trouble<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right; font-weight: bold;\">Temperature Range<\/td>\n<td>:<\/td>\n<td>40\u02daF &#8211; 105\u02daF (5\u02daC &#8211; 40\u02daC)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right; font-weight: bold;\">Sample Connection<\/td>\n<td>:<\/td>\n<td>5\/32\u201d plastic tubing quick connect<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right; font-weight: bold;\">Max Tubing Length<\/td>\n<td>:<\/td>\n<td>350ft per zone (Dependent on system pressure and orifice size)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Installation<\/h2>\n<p>The ECS AdvancedIQ Vent Controller is designed to be mounted directly to the wall at the installation location inside the riser room. Allow access to the front of the cabinet and place the unit in a location near standard vents, and a dedicated electrical connection. For detailed installation and operation please refer to the ECS AdvancedIQ Vent Controller Manual.<\/p>\n<h2>Cabinet Dimensions<\/h2>\n<p>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"690\" height=\"897\" src=\"https:\/\/demo8.alumagubi.com\/alumaid\/wp-content\/uploads\/2025\/07\/ecsavc-2.png\" alt=\"\" srcset=\"https:\/\/demo8.alumagubi.com\/alumaid\/wp-content\/uploads\/2025\/07\/ecsavc-2.png 690w, https:\/\/demo8.alumagubi.com\/alumaid\/wp-content\/uploads\/2025\/07\/ecsavc-2-231x300.png 231w\" sizes=\"100vw\" \/><br \/>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"548\" height=\"918\" src=\"https:\/\/demo8.alumagubi.com\/alumaid\/wp-content\/uploads\/2025\/07\/ecsavc-3.png\" alt=\"\" srcset=\"https:\/\/demo8.alumagubi.com\/alumaid\/wp-content\/uploads\/2025\/07\/ecsavc-3.png 548w, https:\/\/demo8.alumagubi.com\/alumaid\/wp-content\/uploads\/2025\/07\/ecsavc-3-179x300.png 179w\" sizes=\"100vw\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>AVC-6 ECS AdvancedIQ Vent Controller Nitrogen Generator Corrosion Monitoring General Description The ECS AdvancedIQ Vent Controller provides automatic oxygen venting and monitoring of nitrogen\/oxygen concentration levels within each dry\/preaction fire sprinkler system. As a fire sprinkler system is filled with a continuous supply of nitrogen gas from the ECS AdvancedIQ Nitrogen Generator System, the ECS &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/demo8.alumagubi.com\/alumaid\/avc-6-ecs-advancediq-vent-controller\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;AVC-6 ECS AdvancedIQ Vent Controller&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[54],"tags":[],"class_list":["post-14209","post","type-post","status-publish","format-standard","hentry","category-mep"],"acf":[],"_links":{"self":[{"href":"https:\/\/demo8.alumagubi.com\/alumaid\/wp-json\/wp\/v2\/posts\/14209","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/demo8.alumagubi.com\/alumaid\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/demo8.alumagubi.com\/alumaid\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/demo8.alumagubi.com\/alumaid\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/demo8.alumagubi.com\/alumaid\/wp-json\/wp\/v2\/comments?post=14209"}],"version-history":[{"count":16,"href":"https:\/\/demo8.alumagubi.com\/alumaid\/wp-json\/wp\/v2\/posts\/14209\/revisions"}],"predecessor-version":[{"id":14386,"href":"https:\/\/demo8.alumagubi.com\/alumaid\/wp-json\/wp\/v2\/posts\/14209\/revisions\/14386"}],"wp:attachment":[{"href":"https:\/\/demo8.alumagubi.com\/alumaid\/wp-json\/wp\/v2\/media?parent=14209"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/demo8.alumagubi.com\/alumaid\/wp-json\/wp\/v2\/categories?post=14209"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/demo8.alumagubi.com\/alumaid\/wp-json\/wp\/v2\/tags?post=14209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}